5/15/2023 0 Comments Bullard 41 af filterTherefore, do not connect the filter directly to the compressor exhaust manifold. Temperature: Air supplied to the filter should not exceed 140° F (60° C). Refer to your respirator or pneumatic tool instruction manual to find the appropriate air pressures required for correct use of the equipment. Air discharging from the filter can be controlled to meet specific air pressure requirements by using the pressure regulator adjustment knob. Air will be released by the pressure relief valve when pressure within the filter exceeds 125 psig (8.6 bar). Air Pressure: The air pressure at the filter inlet should not exceed 100 psig (6.89 bar). It is available from: Compressed Gas Association, 1235 Jefferson Davis Highway, Arlington, VA 22202. Commodity Specifications G7.1 for complete details. No toxic contaminants at levels which would make the air unsafe to breathe.Hydrocarbons (condensed) 5 mg/m 3 max.The requirements for Grade D breathable air include: The Bullard airline filter does not remove carbon monoxide and other toxic gases from the air being supplied. Quality of Breathing Air: Supplied breathing air passing through this filter to a respirator must meet at least the requirements for Type 1 gaseous air as described in the Compressed Gas Association Commodity Specification G7.1 (Grade D or higher), as specified by federal law 42 CFR, Part 84, Subpart J, 84.141(b). The law also requires that breathing air hose couplings be incompatible with outlets for other gas systems in order to prevent accidental connection of a supplied air respirator to nonrespirable gases or oxygen. If only a high temperature alarm is used, you must frequently test the compressor air for carbon monoxide to ensure it meets the Grade D requirements discussed below. Air Source Monitoring: Federal Law requires use of carbon monoxide and/or high temperature monitors or alarms when oil lubricated compressors are used as sources of breathing air. Failure to ensure breathable air source could result in death or serious injury. Warning When using a respirator, do not connect the filter to any air source unless you are certain it supplies breathable air. The handle is inserted in the two openings and the threaded ends of the handle are bolted down from the underside, using the lock washers and nuts provided. The handle is mounted by removing the bolts from the 2 positions shown in Figure 1. Handle Kit: An optional handle kit is available for the 41 Series Airline filters. Use Teflon ® tape or thread sealant on the male threads before installing. Assembly (41P6 only) Install the regulator inlet assembly by screwing the 1’’ male nipple on the end of the assembly into the 1’’ female inlet port on the filter body. Tighten the connections to prevent leaks and possible pressure loss. Connect the respirator or pneumatic tool airline hose to the filter outlet. Connection: Connect compressor hose to the air inlet. Failure to follow this instruction could result in death or serious injury. Warning Filter must be mounted securely on a suitable base to prevent tipping over during use. If wall mounting is desired, use the Model 41P6WM, which is designed with a wall-mount bracket. Bolt the filter in position using the mounting legs. Location: Select a flat, stable location to mount the filter. Bullard airline filters will NOT remove carbon monoxide and other toxic gases from the airline. The Bullard 41 Series Airline Filters can be used to remove water, oil, particulates, odors and organic vapors so that cleaner air is delivered to workers or equipment. They can also be used to supply drier, cleaner air to pneumatic tools and systems. 41 Series Airline Filters User Manual 41P2/41P2E 41P6 Bullard 41 Series Airline Filters can be used in conjunction with other compressor safeguards to supply cleaner air to airline respirators.
0 Comments
Leave a Reply. |